ilog.tgo.model.IltAlarm
, that you can directly insert in a Rogue Wave® JViews TGO data source and
represent graphically in a table or tree component connected to the
data source.
Attribute
Name |
Value
Class |
Description
|
---|---|---|
ackSystemId
|
String
|
Identifier
of the system used by the author of the last modification of
the acknowledged state. |
ackTime
|
java.util.Date
|
Date of
the last modification of the acknowledged state. |
ackUserId
|
String
|
Identifier
of the author of the last modification of the acknowledged
state. |
additionalText
|
String
|
Additional
information about the alarm. |
alarmAckState
|
Boolean
|
The
acknowledged state of the alarm. |
alarmChangedTime
|
java.util.Date
|
Date of
the last modification of alarm attribute values. |
alarmClearedTime
|
java.util.Date
|
Date
when the perceived severity of the alarm was changed to
Cleared. |
alarmRaisedTime
|
java.util.Date
|
Date
when the alarm was raised. |
alarmType
|
IltAlarm.AlarmType
|
The type
of alarm. |
attributesChanges
|
Object
|
The list
of changed attributes. |
backedUpStatus
|
Boolean
|
The
backup status. Indicates whether the managed object has a
backup object. |
backUpObject
|
String
|
Distinguished
name of the backup object. |
clearSystemId
|
String
|
Identifier
of the system used by the author of the last request to clear
the alarm. |
clearUserId
|
String
|
Identifier
of the author of the last request to clear the alarm. |
comments
|
Object
|
List of
comments. |
correlatedNotifications
|
Object
|
The
correlated notifications. This attribute identifies a set of
notifications to which this notification is considered to be
correlated. |
graphicRepresentation
|
Fake
attribute used to make it possible to display the alarm object
in one column of a table. This attribute cannot be set a value
directly. |
|
managedObjectClass
|
String
|
Managed
object class of the managed object instance in which the alarm
occurred. |
managedObjectInstance
|
String
|
The managed object instance in which the alarm occurred. See Setting the alarm counters.
|
monitoredAttributes
|
Object
|
The
attributes that are monitored. |
notificationId
|
String
|
Identifier
of the notification that carries the alarm information. |
perceivedSeverity
|
IltAlarmSeverity
|
The
perceived severity of the alarm. It indicates the relative
level of urgency for operator attention.
Values are defined in
IltAlarm.Severity
for raw alarms, and in
IltAlarm.ImpactSeverity
for impact alarms.
The perceived severity is used to
determine the color of the alarm icon in table and tree
components. |
probableCause
|
IltAlarm.ProbableCause
|
The
probable cause of the alarm. |
proposedRepairActions
|
String
|
The
proposed repair actions. |
specificProblem
|
String
|
The
specific problem.
Provides more information on the alarm than
probableCause
.
|
systemDN
|
String
|
The
distinguished name of the system that detected the network
event and generated the notification. |
thresholdInfo
|
Object
|
The
information about the threshold. |
trendIndication
|
IltAlarm.TrendIndication
|
The
trend indication.
This attribute indicates whether the
observed condition is getting better, worse, or is unchanged. |
IltAlarm
also provides convenience methods, such as getPerceivedSeverity and setPerceivedSeverity, that you can use
directly to access each individual predefined attribute of the
class.
IltAlarm
: